Model 024A Met OneWind Direction SensorRevision: 10/12 Copyright © 1989-2012Campbell Scientific, Inc.

Strany 2

024A Met-One Wind Direction Sensor 4.2 Step 2 — Use SCWin Short Cut to Program Datalogger and Generate Wiring Diagram The simplest method for program

Strany 3 - Warranty

024A Met-One Wind Direction Sensor 3. Select 024A Wind Direction Sensor and select the right arrow to add it to the list of sensors to be measured th

Strany 4 - Assistance

024A Met-One Wind Direction Sensor 5. Wire according to the wiring diagram generated by SCWin Short Cut. 5. Overview Met One's 024A is a wind

Strany 5 - Table of Contents

024A Met-One Wind Direction Sensor 6. Specifications Compatible Dataloggers: CR200(X) CR800 series CR1000 CR3000 CR5000 CR9000(X)

Strany 6 - Figures

024A Met-One Wind Direction Sensor 7.2 Mounting Options The 024A can be attached to a CM202, CM204, or CM206 crossarm via a 17953 NU-RAIL fitting (se

Strany 7 - 3. Initial Inspection

024A Met-One Wind Direction Sensor 7.3 Wiring FIGURE 7-3. Schematic of 024A Wind Direction Sensor FIGURE 7-3 and TABLE 7-1 shows wiring; a detailed

Strany 8 - 4. Quickstart

024A Met-One Wind Direction Sensor codes, and delays for CSI dataloggers are listed in TABLE 7-2. The process for determining the correct multiplier

Strany 9

024A Met-One Wind Direction Sensor 7.4.3 Example Programs For these examples, the multiplier is listed as 1. The multiplier is unique to individual

Strany 10

024A Met-One Wind Direction Sensor 'Main Program BeginProg Scan(5,Sec,1,0) 'Default Datalogger Battery Voltage measurement Batt_Volt:

Strany 11

024A Met-One Wind Direction Sensor ;{CR10X} ; *Table 1 Program 01: 10 Execution Interval (seconds) ;Measure sensor. Multiplier is unique to indivi

Strany 13 - 7. Installation

024A Met-One Wind Direction Sensor FIGURE 8-1. Cable diagram 14

Strany 14 - 7.2 Mounting Options

024A Met-One Wind Direction Sensor FIGURE 8-2. Parts diagram 15

Strany 15 - 7.4 Programming

024A Met-One Wind Direction Sensor TABLE 8-1. Met-One Parts List Reproduced by Campbell Scientific, Inc. Item Part No. Description. Qty./Assy 1 102

Strany 16

024A Met-One Wind Direction Sensor 9. References The following references give detailed information on siting wind speed and wind direction sensors.

Strany 17 - 7.4.3 Example Programs

024A Met-One Wind Direction Sensor 18

Strany 18

Appendix A. Wind Direction Sensor Orientation A.1 Determining True North and Sensor Orientation Orientation of the wind direction sensor is done af

Strany 19 - 8. Maintenance

Appendix A. Wind Direction Sensor Orientation FIGURE A-1. Magnetic declination for the contiguous United States (2004) A-2

Strany 20 - FIGURE 8-1. Cable diagram

Appendix A. Wind Direction Sensor Orientation FIGURE A-2. Declination angles east of True North are subtracted from 0 to get True North FIGURE A-3

Strany 21 - FIGURE 8-2. Parts diagram

Appendix A. Wind Direction Sensor Orientation A-4

Strany 23 - 9. References

Warranty “PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in materi

Strany 24

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Strany 25 - Orientation

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Strany 26

Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to spec

Strany 27

Table of Contents ii Figures 4-1. Bushing installation on 024A sensor ... 2 4-2. The 024A mounted to

Strany 28

024A Met-One Wind Direction Sensor 1. Introduction The 024A is a wind vane manufactured by Met One. It measures wind direction only and is traditio

Strany 29

024A Met-One Wind Direction Sensor 4. Quickstart 4.1 Step 1 — Mount the Sensor Please review Section 7, Installation, for siting and other guideline

Strany 30

024A Met-One Wind Direction Sensor 7. Align the sensor so that the counter weight points to True South and tighten the U-bolts on the CM220 or tighte