110PV SurfaceTemperature ProbeRevision: 10/11Copyright © 2010-2011Campbell Scientific, Inc.
110PV Surface Temperature Probe Uncertainty on the graphs below is symmetric about 0. FIGURE 2-2. 110PV measured with a 3-wire half bridge FIGURE 2
110PV Surface Temperature Probe FIGURE 2-4. 110PV measured with a CR1000 showing effects of cable length when using a cable offset FIGURE 2-5. 110
110PV Surface Temperature Probe FIGURE 2-6. 110PV measured with a CR200(X) showing effects of cable length when a cable offset is used FIGURE 2-7.
110PV Surface Temperature Probe 3. Installation and Wiring 3.1 Placement on a Photovoltaic (PV) Module The 110PV should be centered on the back of t
110PV Surface Temperature Probe 3.2 Mounting to a PV Module or Other Device For mounting the probe to the back of a PV module or another device, the
110PV Surface Temperature Probe FIGURE 3-4. 110PV’s strain relief label 3.4 Submersion The 110PV can be submerged to 50 ft. It must be adhered to
110PV Surface Temperature Probe TABLE 4-1. Connections to Campbell Scientific Dataloggers Color Description 4-Wire Half Bridge CR800
110PV Surface Temperature Probe 5.1 CRBasic The CR200(X)-series dataloggers use the ExDelSe instruction to measure the 110PV (see example in Section
110PV Surface Temperature Probe 5.1.1.1 Sample Program for CR200(X) Series Datalogger 'CR200 Series Datalogger 'This example program measur
110PV Surface Temperature Probe 'Convert Celsius to Fahrenheit T110PV_Temp_F = T110PV_Temp_C * 1.8 + 32 'Call AvgTemp data tabl
110PV Surface Temperature Probe BeginProg Scan (1,Sec,3,0) ' Measure 110PV-L probe BrHalf (T110PV_mV,1,mV2500,1,Vx1,1,2500,True ,0,_60H
110PV Surface Temperature Probe 'Define a data table for 10 minute averages DataTable (AvgTemp,1,1000) DataInterval (0,10,Min,10) Average (1,
110PV Surface Temperature Probe Example Program for CR10X ;{CR10X} ;This program measures a single 110PV-L probe utilizing the ;P5 instruction once a
110PV Surface Temperature Probe ;Every ten minutes set output flag high to write data final storage 7: If time is (P92) 1: 0000 Minutes (Second
110PV Surface Temperature Probe 6. Measurement Understanding the details in this section is not necessary for general operation of the 110PV Probe w
110PV Surface Temperature Probe 7. Maintenance, Removal, and Calibration 7.1 Maintenance The 110PV probe requires minimal maintenance. Periodically
110PV Surface Temperature Probe 20 Symptom: Unstable Temperature Try using the 60 or 50 Hz integration options, and/or increasing the settling time a
Appendix A. Probe Material Properties The probe consists of 6061 aluminum (clear anodized), thermistor, 3M9485PC adhesive, and Santoprene jacketed ca
Appendix A. Probe Material Properties A-2
Appendix A. Probe Material Properties A-3
Warranty “PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in materi
Appendix A. Probe Material Properties A-4
Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel
Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing
110PV Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to
110PV Table of Contents ii Figures 1-1. 110PV Temperature Probe ... 1 2-1. Steinha
110PV Surface Temperature Probe 1. General The 110PV-L temperature probe uses a thermistor to measure temperature. The probe is designed for measuri
110PV Surface Temperature Probe The 110PV ships with: 1) Adhesive Backed 3 cm Cable Tie Mount 2) Cable Ties 8” UV Stabilized 3) Resource CD 1.1 Sp
110PV Surface Temperature Probe 2. Accuracy The overall probe accuracy is a combination of the thermistor's interchangeability specification and
Komentáře k této Příručce