3WHB10K 3-Wire Half Bridge
Terminal Input Module
Revision: 12/06
Copyright © 1996-2006
Campbell Scientific, Inc.
H
L
AG
H
L
AG
H
L
G
Zobrazit stránku 0
1 2 3 4 5 6 ... 13 14

Shrnutí obsahu

Strany 1 - Terminal Input Module

3WHB10K 3-Wire Half Bridge Terminal Input ModuleRevision: 12/06Copyright © 1996-2006Campbell Scientific, Inc.HLAGHLAGHLG

Strany 2 - Warranty and Assistance

3WHB10K 3-Wire Half Bridge Terminal Input Module 6 The result of the 3-wire half bridge instruction is equivalent to the ratio of the PRT resistance,

Strany 3 - 3WHB10K Table of Contents

3WHB10K 3-Wire Half Bridge Terminal Input Module 7 To perform the calibration, connect the PRT to the datalogger and program the datalogger to measure

Strany 4

3WHB10K 3-Wire Half Bridge Terminal Input Module 8 This is a blank page.

Strany 5 - Input Module

This is a blank page.

Strany 6 - 3. Wiring

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com info@campbells

Strany 7 - 4.1 CR10(X)

Warranty and Assistance The 3WHB10K 3-WIRE HALF BRIDGE TERMINAL INPUT MODULE is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in mate

Strany 8 - 4.3 CR7

i 3WHB10K Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab

Strany 9 - 4.5 CR1000

This is a blank page.

Strany 10 - 5.2 Calibrating a PRT

1 3WHB10K 3-Wire Half Bridge Terminal Input Module 1. Function Terminal input modules connect directly to the datalogger's input terminals to pr

Strany 11

3WHB10K 3-Wire Half Bridge Terminal Input Module 2 3. Wiring ShieldABHLG10 kΩDataloggerVxHL or AG or G FIGURE 3-1. 3-Wire Half Bridge Used to Measur

Strany 12 - This is a blank page

3WHB10K 3-Wire Half Bridge Terminal Input Module 3 TABLE 4-1. Excitation Voltage for 100 Ohm PRT in 3WHB10K Based on Maximum Temperature and Input V

Strany 13

3WHB10K 3-Wire Half Bridge Terminal Input Module 4 4.2 21X 1: 3W Half Bridge (P7) 1: 1 Reps 2: 3 ± 50 mV Slow Range 3: 1 SE Channel 4:

Strany 14

3WHB10K 3-Wire Half Bridge Terminal Input Module 5 4.4 CR9000X 'CR9000X Datalogger Public RS_Ro, Temp_F DataTable (Temp_F,1,-1) DataInterval (