Campbell-scientific 014A Met One Wind Speed Sensor Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Měřící nástroje Campbell-scientific 014A Met One Wind Speed Sensor. Campbell Scientific 014A Met One Wind Speed Sensor User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - INSTRUCTION MANUAL

INSTRUCTION MANUAL Model 014A Met One Wind Speed Sensor Revision: 4/14 Copyright © 1980- 2014 Campbell Scientific, Inc.

Strany 2

Met One 014A Wind Speed Sensor 4. Quickstart 4.1 Assemble and Mount the Sensor 4.1.1 Tools Required • 5/64 inch Allen wrench (shipped with the 014

Strany 3 - Limited Warranty

Met One 014A Wind Speed Sensor FIGURE 4-2. Allen wrench tightening bolt 4. Ensure that the cup assembly spins freely. 4.1.3 Mount to a Tripod or T

Strany 4 - Assistance

Met One 014A Wind Speed Sensor 5. Route the sensor cable along the underside of the crossarm to the tripod/tower, and to the instrument enclosure. 6.

Strany 5 - Precautions

Met One 014A Wind Speed Sensor 4.2 Use SCWin to Program Datalogger and Generate Wiring Diagram Short Cut is an easy way to program your datalogger to

Strany 6

Met One 014A Wind Speed Sensor 4. Select Datalogger Model and Scan Interval (default of 5 seconds is OK for most applications). Click Next. 5. Un

Strany 7 - Table of Contents

Met One 014A Wind Speed Sensor 6. After selecting the sensor, click at the left of the screen on Wiring Diagram to see how the sensor is to be wired

Strany 8 - Figures

Met One 014A Wind Speed Sensor TABLE 5-1. Recommended Lead Lengths CM106 CM110 CM115 CM120 UT10 UT20 UT30 14 ft 14 ft 19 ft 24 ft 14 ft 24

Strany 9 - 3. Initial Inspection

Met One 014A Wind Speed Sensor 7. Installation If you are programming your datalogger with Short Cut, skip Section 7.3, Wiring, and Section 7.4, Prog

Strany 10 - 4. Quickstart

Met One 014A Wind Speed Sensor 7.3 Wiring The 014A is typically connected to a datalogger’s pulse port (see TABLE 7-1). TABLE 7-1. Connections to

Strany 11

Met One 014A Wind Speed Sensor Short Cut cannot edit programs after they are imported and edited in CRBasic Editor. A Short Cut tutorial is available

Strany 13 - Diagram

Met One 014A Wind Speed Sensor 8.1.2 12 to 24 Month Service Replace sensor bearings. 8.1.3 24 to 36 Month Service A complete factory overhaul of the

Strany 14

Met One 014A Wind Speed Sensor The State Climatologist, 1985: Publication of the American Association of State Climatologists: Height and Exposure S

Strany 15 - 5. Overview

Met One 014A Wind Speed Sensor 14

Strany 16 - 6. Specifications

Appendix A. Importing Short Cut Code This tutorial shows: • How to import a Short Cut program into a program editor for additional refinement. • H

Strany 17 - 7. Installation

Appendix A. Importing Short Cut Code 5. The program can now be edited, saved, and sent to the datalogger. 6. Import wiring information to the progr

Strany 18 - 7.4 Programming

Appendix B. Example Programs B.1 Pulse Port Examples The following CR1000 and CR10X programs use a pulse port to measure the 014A every 5 seconds.

Strany 19 - 8. Maintenance

Appendix B. Example Programs B.1.2 CR10X Example Program ;{CR10X} *Table 1 Program 01: 5.0000 Execution Interval (seconds) 1: Batt Voltage (

Strany 20 - 10. References

Appendix B. Example Programs B.2 Control Port Example Program The following CR5000 program uses control ports to measure three 014A wind speed senso

Strany 21

Appendix B. Example Programs B-4

Strany 22

Appendix C. Sensor Maintenance C.1 Reed Switch Replacement Procedure To verify parts and locations, refer to the cable and parts diagrams (FIGURE C

Strany 23 - A.1.1 CRBasic Dataloggers

Limited Warranty “Products manufactured by CSI are warranted by CSI to be free from defects in materials and workmanship under normal use and service

Strany 24 - A.1.2 Edlog Dataloggers

Appendix C. Sensor Maintenance C. Insert a right-angle type of tool, such as an Allen wrench, into bearing. Cock it slightly to one side and remove

Strany 25 - B.1 Pulse Port Examples

Appendix C. Sensor Maintenance FIGURE C-3. Parts diagram C-3

Strany 26 - B.1.2 CR10X Example Program

Appendix C. Sensor Maintenance TABLE C-1. Met One Parts List Reproduced by Campbell Scientific, Inc. Item Part No. Description Qty./Assy 1 10116

Strany 27

Appendix D. Theory of Operation D.1 Mechanical The sensor’s cup assembly consists of three aluminum cups mounted on a cup assembly hub. A stainles

Strany 28

Appendix D. Theory of Operation D-2

Strany 30

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbe

Strany 31 - FIGURE C-3. Parts diagram

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Strany 32

Precautions DANGER — MANY HAZARDS ARE ASSOCIATED WITH INSTALLING, USING, MAINTAINING, AND WORKING ON OR AROUND TRIPODS, TOWERS, AND ANY ATTACHMENTS TO

Strany 34

Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to spec

Strany 35

Table of Contents A.1.2 Edlog Dataloggers ...... A-2 B. Example Programs ...

Strany 36

Met One 014A Wind Speed Sensor 1. Introduction The 014A is a three-cup anemometer that monitors horizontal wind speed for the range of 0 to 45 m s–1