Campbell-scientific 014A Met One Wind Speed Sensor Uživatelský manuál Strana 16

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 36
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 15
Met One 014A Wind Speed Sensor
TABLE 5-1. Recommended Lead Lengths
CM106 CM110 CM115 CM120 UT10 UT20 UT30
14 ft 14 ft 19 ft 24 ft 14 ft 24 ft 37 ft
The 014A’s cables can terminate in:
Pigtails that connect directly to a Campbell Scientific datalogger
(cable termination option PT).
Connector that attaches to a prewired enclosure (cable termination
option PW).
6. Specifications
Features:
Ideal for applications that do not require wind direction
measurements
Sealed magnetic reed switch
Designed for continuous, long term, unattended operation in adverse
conditions
Compatible with Campbell Scientific CRBasic dataloggers:
CR200(X) series, CR800 series, CR1000, CR3000, CR5000, and
CR9000(X). Also compatible with Edlog dataloggers: CR500,
CR510, CR10(X), CR23X, 21X, and CR7
Threshold: 0.45 m s
–1
(1 mph)
Calibrated Range: 0 to 45 m s
–1
(0 to 100 mph)
Gust Survival: 0 to 53 m s
–1
(0 to 120 mph)
Accuracy: 1.5% or 0.11 m s
–1
(0.25 mph)
Temperature Range: 50° to +70°C
Output Signal: Contact Closure, Reed Switch
Weight: 680 g (1.5 lb)
6.1 Distance Constant*
Standard: Less than 4.6 m (15 ft)
(Aluminum Cups)
Optional Fast Response: Less than 1.5 m (5 ft)
(Lexan Cups)
* The distance traveled by the air after a sharp-edged gust has occurred for the
anemometer to reach 63% of the new speed.