Campbell-scientific WINDSONIC 2-D Sonic Wind Sensors Uživatelský manuál Strana 18

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 46
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 17
WindSonic Two-Dimensional Sonic Anemometer
White Dot
FIGURE 6-1. White dot indicating that the WindSonic1 has the newer
settings
7. Operation
7.1 Sensor Configuration
In order to best mimic a mechanical anemometer, the WindSonic’s output
frequency must match the datalogger’s scan frequency. The factory setting for
the WindSonic1 and WindSonic4 is 1 Hz; for example, 1 output per second.
The data output frequency of the WindSonic4 cannot be changed.
The data output frequency of the WindSonic1 can be set to five discrete values
(see TABLE 7-1) using Gill’s PC support software and the RS-232 WindSonic
to PC cable.
TABLE 7-1. WindSonic1
Output Frequencies
Output
Frequency (Hz)
Seconds
Per Output (s)
4 0.25
2 0.5
1 1
0.5 2
0.25 4
10
Zobrazit stránku 17