Campbell-scientific WINDSONIC 2-D Sonic Wind Sensors Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Měřící nástroje Campbell-scientific WINDSONIC 2-D Sonic Wind Sensors. Campbell Scientific WINDSONIC 2-D Sonic Wind Sensors User Manual [en] [ru] [de] [es] [fr] [pl] Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 46
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
WindSonic Two-Dimensional
Sonic Anemometer
Revision: 8/13
Copyright © 2004-2013
Campbell Scientific, Inc.
Zobrazit stránku 0
1 2 3 4 5 6 ... 45 46

Shrnutí obsahu

Strany 1 - Sonic Anemometer

WindSonic Two-Dimensional Sonic AnemometerRevision: 8/13 Copyright © 2004-2013Campbell Scientific, Inc.

Strany 2

WindSonic Two-Dimensional Sonic Anemometer • The black outer jacket of the cable is Santoprene® rubber. This compound was chosen for its resistance

Strany 3 - Warranty

WindSonic Two-Dimensional Sonic Anemometer 5. Mount the crossarm to the tripod or tower. 6. Orient the WindSonic so that the colored North marker ar

Strany 4 - Assistance

WindSonic Two-Dimensional Sonic Anemometer 4.3 Use Short Cut Program Generator for Windows (SCWin) to Program Datalogger and Generate Wiring Diagram

Strany 5 - Table of Contents

WindSonic Two-Dimensional Sonic Anemometer 3. Select WindSonic4 (SDI-12) Two Dimensional Ultrasonic Wind Sensor and select the right arrow (in center

Strany 6

WindSonic Two-Dimensional Sonic Anemometer 5. Select the outputs and then select finish. 6. Wire according to the wiring diagram generated by SCWi

Strany 7

WindSonic Two-Dimensional Sonic Anemometer 5. Overview The WindSonic is an ultrasonic anemometer for measuring wind direction and wind speed. It use

Strany 8

WindSonic Two-Dimensional Sonic Anemometer 6. Specifications Features: • Low maintenance—no moving parts significantly reduces maintenance cost and

Strany 9 - Anemometer

WindSonic Two-Dimensional Sonic Anemometer 6.4 Campbell Scientific Factory Default Settings for the WindSonic1 The default settings for the WindSonic

Strany 10 - 4. Quickstart

WindSonic Two-Dimensional Sonic Anemometer White DotFIGURE 6-1. White dot indicating that the WindSonic1 has the newer settings 7. Operation 7.1 S

Strany 11

WindSonic Two-Dimensional Sonic Anemometer 7.2 Wiring 7.2.1 Serial Wiring (COMn) CRBasic dataloggers (CR800 series, CR1000, and CR3000) support seri

Strany 13

WindSonic Two-Dimensional Sonic Anemometer 7.2.3 SDI-12 Wiring The WindSonic4 interfaces to a Campbell Scientific datalogger using SDI-12. SDI-12 is

Strany 14

WindSonic Two-Dimensional Sonic Anemometer TABLE 7-5. CRBasic Datalogger OperatingSystems that Support RS-232 Communications and SerialInRecord() Da

Strany 15 - 5. Overview

WindSonic Two-Dimensional Sonic Anemometer FieldNames ("diag_10_TOT") Totalize (1,n,IEEE4,nmbr_bytes_rtrnd<>0) FieldNames ("

Strany 16 - 6. Specifications

WindSonic Two-Dimensional Sonic Anemometer Totalize (1,n,IEEE4,diag<>2) FieldNames ("diag_2_TOT") Totalize (1,n,IEEE4,diag<&g

Strany 17 - WindSonic1

WindSonic Two-Dimensional Sonic Anemometer The WindSonic4 returns three data points; the datalogger program must allocate three consecutive input loca

Strany 18 - 7. Operation

WindSonic Two-Dimensional Sonic Anemometer 7.4.1 Example CR10X (Edlog) Datalogger Program for Measuring a WindSonic4 TABLE 7-10. Wiring for CR10(X)

Strany 19 - 7.2 Wiring

WindSonic Two-Dimensional Sonic Anemometer 8: If (X<=>F) (P89) 1: 3 X Loc [ ws_diag ] 2: 2 <> 3: 0 F 4: 19 Set Inte

Strany 20 - 7.2.3 SDI-12 Wiring

WindSonic Two-Dimensional Sonic Anemometer 17: If (X<=>F) (P89) 1: 3 X Loc [ ws_diag ] 2: 1 = 3: 8 F 4: 29 Set Intermed.

Strany 21

WindSonic Two-Dimensional Sonic Anemometer *Table 3 Subroutines End Program -Input Locations- 1 wnd_dir 2 wnd_spd 3 ws_diag 4 samples 7.4.2 Exampl

Strany 22

WindSonic Two-Dimensional Sonic Anemometer Totalize (1,one,diag<>NaN) FieldNames ("no_data_TOT") EndTable BeginProg one = 1 Scan

Strany 23

Warranty “PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in materi

Strany 24

WindSonic Two-Dimensional Sonic Anemometer Totalize (1,one,IEEE4,diag<>10) FieldNames ("diag_10_TOT") Totalize (1,one,IEEE4,diag<

Strany 25 - WindSonic4

WindSonic Two-Dimensional Sonic Anemometer • To activate the SDI-12 Transparent Mode, on Control Port p, enter pX and press the <enter> key. T

Strany 26

WindSonic Two-Dimensional Sonic Anemometer 7.5.2 Table-Based Edlog Dataloggers • Connect a single WindSonic4 to the datalogger Control Port p as des

Strany 27

WindSonic Two-Dimensional Sonic Anemometer FIGURE 7-2. SDI-12 Transparent Mode on an Edlog table-based datalogger using control port 8 and changing

Strany 28

WindSonic Two-Dimensional Sonic Anemometer press the <enter> key. The WindSonic4 will respond with the current SDI-12 address. • To change the

Strany 29

WindSonic Two-Dimensional Sonic Anemometer (refer to the Assistance section at the beginning of this manual for the process of returning a product to

Strany 30 - Datalogger

WindSonic Two-Dimensional Sonic Anemometer 28 10. Siting References The following references give detailed information on siting wind direction and w

Strany 31

Appendix A. WindSonic Orientation A.1 Determining True North and Sensor Orientation The orientation of the WindSonic “North Arrow Markers” is found

Strany 32

Appendix A. WindSonic Orientation Declination angles east of True North are considered negative, and are subtracted from 360 degrees to get True Nort

Strany 33

Appendix A. WindSonic Orientation A.2 Online Magnetic Declination Calculator The magnetic declination calculator web calculator published by NOAA’s

Strany 34 - 8. Maintenance

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Strany 35 - 9. Diagnostic Codes

Appendix A. WindSonic Orientation A-4

Strany 36 - 10. Siting References

Appendix B. Updating an Older Program for Measuring a WindSonic1 With the New Settings In February 2013, the settings of the WindSonic1 sensor were

Strany 37

Appendix B. Updating an Older Program for Measuring a WindSonic1 With the New Settings New CR1000 Program (Section 7.3.1) (Public variables change.

Strany 38

Appendix B. Updating an Older Program for Measuring a WindSonic1 With the New Settings New CR1000 SDM-SIO1 Program (from Section 7.3.2) (Public varia

Strany 39

Appendix B. Updating an Older Program for Measuring a WindSonic1 With the New Settings B-4

Strany 41 - With the New Settings

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Strany 42

Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to spec

Strany 43

Table of Contents 7.5 Changing the SDI-12 Address Using LoggerNet and a Datalogger .. 22 7.5.1 Array-Based Edlog Dataloggers...

Strany 44

Table of Contents 7-8. WindSonic Data Format Option...15 7-9. Datalogger Operating Systems tha

Strany 45

Table of Contents iv

Strany 46

WindSonic Two-Dimensional Sonic Anemometer 1. Introduction The WindSonic1 and WindSonic4 are two-dimensional ultrasonic anemometers for measuring wi

Komentáře k této Příručce

Žádné komentáře