Campbell-scientific CS11-L Current Transformer Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Měřící nástroje Campbell-scientific CS11-L Current Transformer. Campbell Scientific CS11-L Current Transformer User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - CS11-L Current Transformer

CS11-L Current Transformer12/13 Copyright © 2001-2013Campbell Scientific, Inc.

Strany 2

CS11-L Current Transformer 'CR1000 Series Datalogger ' CS11-L_with_ACPower_AmpsOnly.CR1 'date: June 24, 2013 ' ' Wiring: &apo

Strany 3 - Warranty

CS11-L Current Transformer Working with live electrical equipment is dangerous! The user is responsible for ensuring all wiring conforms to local saf

Strany 4 - Assistance

CS11-L Current Transformer Option Description 2 Split-phase with one voltage measurement and two current measurements. This configuration is typical

Strany 5 - Table of Contents

CS11-L Current Transformer Option Description 3 Three-phase ‘Y’, four-conductor, configurations with three voltage measurements and three current mea

Strany 6 - Figures

CS11-L Current Transformer MaxVrms The MaxVrms parameter is the expected maximum rms (root mean square) voltage to measure. MaxVrms is specified at

Strany 7

CS11-L Current Transformer Current(RepsI). The measured current in amps rms, repeated to give RepsI values. VPhaseI(RepsI). The measured phase ang

Strany 8 - 3. Installation

CS11-L Current Transformer Current(3). The measured current in Amps rms for each of the three line conductors. VphaseI(3). The measured phase angl

Strany 9 - 5. ACPower Instruction

CS11-L Current Transformer TABLE 6-1. Max Amps on Each of the Range Codes in the Datalogger (one pass only). Datalogger >>> Range Codes (m

Strany 10

CS11-L Current Transformer Below is an example CR1000 program. In the program, a multiplier of 0.2 is applied to the rms value; see Appendix A.4, Mul

Strany 11

CS11-L Current Transformer samples 25 times, and the second CR200X example program has a loop that samples 30 times. A 25-sample loop produces almost

Strany 13

CS11-L Current Transformer EndIf CallTable Amp NextScan EndProg 6.2.2 CR200(X) Program for 50 Hz 'CR200 Series Datalogger ' Program n

Strany 14

CS11-L Current Transformer Six Cycles at 60 Hz Burst CR10X I Instanteneous FIGURE 6-2. Graph of CS11-L waveform using burst mode The following CR10X

Strany 15

CS11-L Current Transformer 3: Beginning of Loop (P87) 1: 0 Delay 2: 50 Loop Count 4: Z=Z+1 (P32) 1: 1 Z Loc [ Counter ] 5:

Strany 16 - 6. Programming

CS11-L Current Transformer The instructions listed below do not store data in final storage. P92, P77, and output processing instructions such as P7

Strany 17

CS11-L Current Transformer 6.5 CR1000 with Multiplexer Sample Program This program uses the CR1000 and an AM16/32-series multiplexer to read 32 CS11-

Strany 18

CS11-L Current Transformer 6.6.1 Example CR10X program reading 32 CS11-L Current Transformers ;{CR10X} ; Example program for CS11-L ; ; Program to te

Strany 19 - CS11-L waveform

CS11-L Current Transformer 10: Do (P86) 1: 3 Call Subroutine 3 11: Z=X (P31) 1: 3 X Loc [ Burst_A2 ] 2: 5 -- Z Loc [ CS11

Strany 20

CS11-L Current Transformer 10: 71 Loc [ Amps_1 ] 11: .2 Multiplier 12: 0.0 Offset 3: Burst Measurement (P23) 1: 1 Inp

Strany 21 - I Instanteneous

CS11-L Current Transformer 22 15: Z=F x 10^n (P30) 1: 0.0 F 2: 00 n, Exponent of 10 3: 1 Z Loc [ Counter ] 16: Beginning

Strany 22 - 6.4 21X, CR7 Dataloggers

Appendix A. Theory of Operation A.1 Typical Electrical Circuit An example of a typical electrical circuit is a generator that provides energy in th

Strany 23 - 6.4.1 Example CR21X Program

Warranty “PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in materi

Strany 24

Appendix A. Theory of Operation CS11-LWire added duringinstallationInternal shape ofthe transformer FIGURE A-3. Schematic of current transformer wi

Strany 25

Appendix A. Theory of Operation The formula for a transformer is as follows (Equation A): i1 • n1 = i2 • n2 Equation A Where i = amps and n = number

Strany 26

Appendix A. Theory of Operation The CS11-L contains a 10-ohm burden (shunt) resistor (R=10 ohm). Therefore, E is: E = 0.01 amps • 10 ohms = 0.1 vo

Strany 27

Appendix A. Theory of Operation 12 3456 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 250-20-40-60-8020406080SamplesmV12 3456 7 8 9 10 11 12 13

Strany 28

Appendix A. Theory of Operation FIGURE A-10. CS11-L with a wire making two passes through the sensor A-6

Strany 30 - Internal shape of

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Strany 31 - Many windings

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Strany 32 - A.5 CS11-L Details

Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to spec

Strany 33 - Adjusted Measurement Range

Table of Contents ii Figures 1-1. CS11-L Current Transformer ... 1 3-1. AC load wire inst

Strany 34

CS11-L Current Transformer 1. General Description Campbell Scientific’s CS11-L (FIGURE 1-1) detects and measures the AC current along an electrical

Strany 35

CS11-L Current Transformer Measurement Ranges: 0.15 to 200 A (0.15 to 125 A for CR200X) Frequency: 50 and 60 Hz Insulation Resistance: 100 M ohm @

Strany 36

CS11-L Current Transformer 4. Wiring The CS11-L uses a single-ended analog channel as follows: Wire Color Terminal RED or AG (VX on CR200X) WHITE

Komentáře k této Příručce

Žádné komentáře