CPEC200 Closed-Path Eddy-Covariance System
FIGURE 5-2. CM210 mounting bracket on a tripod mast
The EC155 gas analyzer and CSAT3A sonic anemometer head are mounted on
the end of the crossarm using the CM250 leveling mount and the CPEC200
mounting platform, as shown in FIGURE 5-3. Adjust the tilt of the mounting
platform to level the CSAT3A. For more details see instructions in the EC155
CO
2
and H
2
O Closed-path Gas Analyzer manual.
FIGURE 5-3. Mounting of EC155 and CSAT3A
CM202 Crossarm
CM210 Crossarm-to-
Pole Bracket
Leveling
Bubble
CSAT3A Sonic
Anemometer Head
EC155
Gas Analyzer
CM20X
Crossarm
CM250 Leveling
Mount
Mounting
Platform
20