Campbell-scientific SM192/SM716 Storage Modules Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Úložný prostor Campbell-scientific SM192/SM716 Storage Modules. Campbell Scientific SM192/SM716 Storage Modules User Manual [en] [es] [fr] Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - INSTRUCTION MANUAL

SM192/716 STORAGE MODULEINSTRUCTION MANUALREVISION: 6/14/93COPYRIGHT (c) 1989, 1993 CAMPBELL SCIENTIFIC, INC.

Strany 2 - WARRANTY AND ASSISTANCE

2-1SECTION 2. STORING DATA FROM CR10, 21X, AND CR7This section covers data storage from the CR10 and from the 21X and CR7 with current software. 21X

Strany 3 - TABLE OF CONTENTS

SECTION 2. STORING DATA FROM CR10, 21X, AND CR72-2CAUTION: Be sure to complete the datatransfer before making any changes in thedatalogger program.

Strany 4 - APPENDICES

SECTION 2. STORING DATA FROM CR10, 21X, AND CR72-32.1.2 USE OF TWO STORAGE MODULES WITH21X OR CR7For large volumes of data, two SMs can beconnected

Strany 5 - 1.1 SPECIFICATIONS

3-1SECTION 3. THE PRINTER ENABLE METHOD OF DATA STORAGEData from the 21X and CR7 with PROMS older than the OSX and OX7 series PROMS and from theCR21

Strany 6 - 1.3 POWER

SECTION 3. THE PRINTER ENABLE METHOD OF DATA STROAGE3-23.2.1 INSTRUCTION 96 - OUTPUT UNDERPROGRAM CONTROLInstruction 96, available in the CR7X and i

Strany 7 - 1.4 FUNCTION

4-1SECTION 4. STORAGE MODULE MEMORY AND DATA ENCODING4.1 FILE MARKSFile Marks are used to separate data in theStorage Module. A File Mark is automa

Strany 8

SECTION 4. STORAGE MODULE MEMORY AND DATA ENCODING4-2receiving data plus 110 usec for each byteremaining in the input buffer after transmissionis com

Strany 9 - 1.5 QUICK START-UP PROCEDURE

5-1SECTION 5. DATA RETRIEVALData retrieval is accomplished on PCs using SMCOM. Other computers require a software programwhich makes use of the Stor

Strany 10 - UNDER PROGRAM CONTROL

SECTION 5. DATA RETRIEVAL5-25.1-1 Storage Module Connected With SC5325.1-2 Storage Module Connected to PC201 Card5.1-3 Communication Via the CR105

Strany 11

SECTION 5. DATA RETRIEVAL5-3Complete details on the operation of SMCOMare contained in the PC208 manual.When using a computer other than an IBMPC/XT/

Strany 12 - DATA FROM THE CR10 OR 21X

WARRANTY AND ASSISTANCEThe SM192/716 STORAGE MODULE is warranted by CAMPBELL SCIENTIFIC, INC. to be free fromdefects in materials and workmanship unde

Strany 13 - OSX AND OS7 RELEASE)

SECTION 5. DATA RETRIEVAL5-46. Send the last carriage return to executethe data retrieval.The same fundamental procedures used in amanually executed

Strany 14 - OPERATIONS

6-1SECTION 6. STORING AND RETRIEVING DATALOGGER PROGRAMSCR10, 21X, and CR7 programs can be uploaded and downloaded between the datalogger and theStor

Strany 15 - 4.3 DATA FORMAT AND INPUT

A-1APPENDIX A. CR10 *9 MODE -- STORAGE MODULE COMMANDSThe CR10 *9 Mode is used to issue commandsto the Storage Module using the CR10KDkeyboard/displa

Strany 16

APPENDIX A. CR10 *9 MODE - STORAGE MODULE COMMANDSA-2COMMAND DISPLAYDESCRIPTION5 DISPLAY STATUS (A to advance to each window)01:ABCD Window 1: AB

Strany 17 - SECTION 5. DATA RETRIEVAL

APPENDIX A. CR10 *9 MODE - STORAGE MODULE COMMANDSA-3COMMAND DISPLAYDESCRIPTION9 DISPLAY ADDRESSES OF CONNECTED SM'SXXXXXXXX 1 = occupied, 0 = u

Strany 18

B-1APPENDIX B. SAMPLE FLOW DIAGRAM FOR DATA RETRIEVALPROGRAM

Strany 19 - 5.3 DATA RETRIEVAL STEPS

C-1APPENDIX C. NON-DATALOGGER APPLICATIONSAll non-datalogger Storage Module operationsare accomplished through the Printer EnableMethod. The Storage

Strany 20

APPENDIX C. NON-DATALOGGER APPLICATIONSC-2C.3 STORAGE MODULE 9-PINCONNECTORThe pins on the 9 pin sub-miniature Dconnector on the Storage Module are

Strany 21 - DATALOGGER PROGRAMS

D-1APPENDIX D. TELECOMMUNICATIONS COMMANDSThe SM Telecommunications Commands canbe used over links through the CR10 or with theStorage Module connect

Strany 22

APPENDIX D. TELECOMMUNICATIONS COMMANDSD-2external power. The battery should then bereplaced.100E LOADED BATTERY TEST: The state ofthe battery is

Strany 23

ISM192/SM716 STORAGE MODULETABLE OF CONTENTSPAGEWARRANTY1. SM192/716 STORAGE MODULE OVERVIEW...

Strany 24

APPENDIX D. TELECOMMUNICATIONS COMMANDSD-3nJ STORE PROGRAM n (n = 1...8): TheStorage Module responds with "<" after whichthe SM will

Strany 25

TABLE OF CONTENTSII4. STORAGE MODULE MEMORY AND DATA ENCODING... 4-14.1 File Marks...

Strany 26 - C.2 OTHER NON-DATALOGGER

1-1SECTION 1. SM192/716 STORAGE MODULE OVERVIEWCampbell Scientific's SM192 and SM716 Storage Modules expand on-site RAM data storage for users o

Strany 27 - CONNECTOR

SECTION 1. SM192/716 STORAGE MODULE OVERVIEW1-2FIGURE 1.2-1. Storage Module and SC12 Cable1.2 PHYSICAL DESCRIPTIONThe Storage Module is housed in a

Strany 28

SECTION 1. SM192/716 STORAGE MODULE OVERVIEW1-3ExpectedBattery Life SM192 SM716@ 25C about 10 yrs. about 6 yrs.@ 50C about 3 yrs. about 2 yrs.@ -25C

Strany 29

SECTION 1. SM192/716 STORAGE MODULE OVERVIEW1-4Figure 1.4-1 Operation with Current CR10, 21X, and CR7Figure 1.4-2 Printer Enable OperationsFigure 1.4

Strany 30

SECTION 1. SM192/716 STORAGE MODULE OVERVIEW1-51.4.4 MEMORY CONFIGURATIONThe Storage Module's memory can beconfigured as either Fill and Stop o

Komentáře k této Příručce