Campbell-scientific LoggerNet Server SDK Uživatelský manuál Strana 1

Procházejte online nebo si stáhněte Uživatelský manuál pro Software Campbell-scientific LoggerNet Server SDK. Campbell Scientific LoggerNet Server SDK User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 178
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
LoggerNet Server
Software Development Kit
Version 4.1
Programmer’s Reference
Revision: 12/11
Copyright © 2004-2011
Campbell Scientific, Inc.
A
ll rights reserved; no part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form o
r
by any means, electronics, mechanical, photocopying, recording, or otherwise without either the prior written permission o
f
the Publisher. This book may not be lent, resold, hired out or otherwise disposed of by way of trade in any form of binding o
r
cover other than that in which it is published, without the prior written consent of the Publisher. The programs in this manual
have been included for their instructional value. The Publisher does not offer any warranties or representations in respect o
f
their fitness for a particular purpose, nor does the Publisher accept any liability for any loss or damage arising from their use.
Zobrazit stránku 0
1 2 3 4 5 6 ... 177 178

Shrnutí obsahu

Strany 1 - Programmer’s Reference

LoggerNet ServerSoftware Development KitVersion 4.1Programmer’s ReferenceRevision: 12/11Copyright © 2004-2011Campbell Scientific, Inc.All rights rese

Strany 2

LoggerNet Software Development Kit Table of Contents 12. CsiLogMonitor Control... 12-1 12.1 Purpose of the CsiL

Strany 3 - Agreement (EULA)

Section 17. CsiDatalogger Control Reference Datalogger.loggerName Name Datalogger.loggerName As String Valid Values Specifies the datalogger or stati

Strany 4

Section 17. CsiDatalogger Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return Datalogger.programS

Strany 5

Section 17. CsiDatalogger Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return Datalogger.serverLo

Strany 6

Section 17. CsiDatalogger Control Reference Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_BUSY Error: The property cannot

Strany 7 - LoggerNet Server Software

Section 17. CsiDatalogger Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_INVALIDARG Er

Strany 8

Section 17. CsiDatalogger Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_BUSY Error: C

Strany 9

Section 17. CsiDatalogger Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return Datalogger.loggerCo

Strany 10

Section 17. CsiDatalogger Control Reference Datalogger.manualPollCancel() Name Datalogger.manualPollCancel() Description This method should be calle

Strany 11 - Appendix

Section 17. CsiDatalogger Control Reference Datalogger.programReceiveCancel() Name Datalogger.programReceiveCancel() Description This method attempts

Strany 12 - Figures

Section 17. CsiDatalogger Control Reference Datalogger.programSendCancel() Name Datalogger.programSendCancel() Description This method attempts to c

Strany 13 - Overview

LoggerNet Software Development Kit Table of Contents 17. CsiDatalogger Control Reference ...17-1 17.1 Datalogger Interface ...

Strany 14 - 1.3 Included Components

Section 17. CsiDatalogger Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_BUSY Error: A

Strany 15

Section 17. CsiDatalogger Control Reference Datalogger.serverConnect() Name Datalogger.serverConnect() Description This method attempts to connect t

Strany 16

Section 17. CsiDatalogger Control Reference Parameters successful: Describes whether a clock set or clock check succeeded. response_code: The follow

Strany 17 - 2.2 CsiServer Interface

Section 17. CsiDatalogger Control Reference Enumeration Name Value Description co_outcome_invalid_device_name 9 Indicates that the device named b

Strany 18 - 2.2.3 Events

Section 17. CsiDatalogger Control Reference Enumeration Name Value Description lf_failure_invalid_logon 3 Indicates that this control was unable

Strany 19 - Using the CsiServer Control

Section 17. CsiDatalogger Control Reference Datalogger_onManualPollComplete() Name onManualPollComplete(Boolean successful, manual_poll_outcome_type

Strany 20

Section 17. CsiDatalogger Control Reference Enumeration Name Value Description mp_outcome_communication_disabled 9 Indicates that LoggerNet has b

Strany 21

Section 17. CsiDatalogger Control Reference Datalogger_onProgramReceiveComplete() Name onProgramReceiveComplete(Boolean successful, prog_receive_outc

Strany 22

Section 17. CsiDatalogger Control Reference Enumeration Name Value Description pr_failure_cannot_open_file 9 Indicates that the file could not be

Strany 23

Section 17. CsiDatalogger Control Reference Parameters successful: Describes if the programSendStart was successful. response_code: Found in the tabl

Strany 24 - 4.3.1 Setting up a Network

LoggerNet Software Development Kit Table of Contents vi A.2.10 Collection Enabled ...

Strany 25

Section 17. CsiDatalogger Control Reference Enumeration Name Value Description ps_outcome_cannot_open_file 12 Indicates that the program to send

Strany 26 - 4.4 CsiCoraScript Interface

Section 17. CsiDatalogger Control Reference Datalogger_onProgramSent() Name onProgramSent() Description This event returns notification when the prog

Strany 27 - 5.1 Purpose

Section 17. CsiDatalogger Control Reference Enumeration Name Value Description smp_outcome_server_security_blocked 6 Indicates that the account sp

Strany 28

Section 17. CsiDatalogger Control Reference Enumeration Name Value Description server_failure_session 2 Indicates that the communication session

Strany 29

Section 17. CsiDatalogger Control Reference 17-26

Strany 30

Section 18. CsiDataSource Control Reference 18.1 DSource Interface 18.1.1 Properties DSource.logonName Name DSource.logonName As String Descriptio

Strany 31

Section 18. CsiDataSource Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return. E_CSI_BUSY Error:

Strany 32 - 6.3 How Collections Work

Section 18. CsiDataSource Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return. E_CSI_BUSY Error:

Strany 33 - 6.4.1 BrokerMap Interface

Section 18. CsiDataSource Control Reference Default Value This property is set to FALSE by default. COM Return Values Table of Possible Values Code M

Strany 34 - 6.4.5 Table Interface

Section 18. CsiDataSource Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_NOT_CONNECTED

Strany 35 - 6.4.7 Column Interface

Section 1. LoggerNet Server SDK Overview 1.1 Purpose of the LoggerNet Server SDK The LoggerNet Server Software Development Kit (SDK) provides a meth

Strany 36

Section 18. CsiDataSource Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return DSource_onAdviseRec

Strany 37 - 7.1 Purpose

Section 18. CsiDataSource Control Reference Enumeration Name Value Description csiAdvisorFailureInvalidLogon 2 Indicates that this control was unab

Strany 38

Section 18. CsiDataSource Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return DSource_onControlFa

Strany 39

Section 18. CsiDataSource Control Reference DSource_onControlReady() Name onControlReady() Description This event is triggered when a connection to

Strany 40

Section 18. CsiDataSource Control Reference Enumeration Name Value Description vo_outcome_column_read_only 5 Indicates that the column sent is read

Strany 41 - Section 8. CsiDatalogger

Section 18. CsiDataSource Control Reference Description This event notification returns a block of records delivered by LoggerNet to an active adviso

Strany 42 - 8.3.3 Events

Section 18. CsiDataSource Control Reference Enumeration Name Value Description csidsOrderLoggedWithHoles 2 The records will be sent in the order t

Strany 43 - Using the Datalogger Control

Section 18. CsiDataSource Control Reference Notes This property can be read at any time but can only be set when the state of the property is advisor

Strany 44

Section 18. CsiDataSource Control Reference Advisor.startIntervalSeconds Name Advisor.startIntervalSeconds As Long Description This property specifie

Strany 45

Section 18. CsiDataSource Control Reference Table of possible csidsStartOptionType values Enumeration Name Value Description csidsStartAtRecordId

Strany 46

Section 1. LoggerNet Server SDK Overview The C#.NET and VB.NET example code targets the x86 compilation platform to facilitate proper functionality o

Strany 47 - End Sub

Section 18. CsiDataSource Control Reference Advisor.startRecordNo Name Advisor.startRecordNo As Long Description This property, in conjunction with

Strany 48

Section 18. CsiDataSource Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_BUSY Error: T

Strany 49

Section 18. CsiDataSource Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_BUSY Error: T

Strany 50

Section 18. CsiDataSource Control Reference Advisor.maxRecordsPerBlock Name Advisor.maxRecordsPerBlock As Long Description This property sets the max

Strany 51

Section 18. CsiDataSource Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_ALREADY_CONNEC

Strany 52 - 10.3.2 Advisor Interface

Section 18. CsiDataSource Control Reference Advisor.variableSetStart() Name Advisor.variableSetStart(String column_name, String value) As Long Descr

Strany 53 - 10.3.4 DataColumn Interface

Section 18. CsiDataSource Control Reference 18.3 DataColumnCollection Interface 18.3.1 Properties DataColumnCollection.count Name DataColumnCollect

Strany 54 - 10.3.7 Value Interface

Section 18. CsiDataSource Control Reference DataColumnCollection.addAll() Name DataColumnCollection.addAll() Description This method adds all of the

Strany 55 - 11.1 Purpose

Section 18. CsiDataSource Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_INVALIDARG Er

Strany 56

Section 18. CsiDataSource Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return DataColumnCollecti

Strany 57

Section 1. LoggerNet Server SDK Overview the controls. The standard installation program will register the SDK control DLLs. 1.3.2.1 Adding a Contr

Strany 58

Section 18. CsiDataSource Control Reference unique key for each record. This property can take on any value from 0 to 2147483647. COM Return Values

Strany 59

Section 18. CsiDataSource Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return Record.valuesCount

Strany 60 - 12.2.3 Events

Section 18. CsiDataSource Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_ARRAY_OUT_OF_B

Strany 61 - 13.1 Purpose

Section 18. CsiDataSource Control Reference 18.6 RecordCollection 18.6.1 Properties RecordCollection.Count Name RecordCollection.Count As Long Desc

Strany 62

Section 18. CsiDataSource Control Reference 18-30 18.7 Value Interface 18.7.1 Properties Value.columnName Name Value.columnName As String Descripti

Strany 63

Section 19. CsiLogMonitor Control Reference 19.1 LogMonitor Interface 19.1.1 Properties LogMonitor.commLogMonitorBusy Name LogMonitor.commLogMonito

Strany 64

Section 19. CsiLogMonitor Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_INVALIDARG Er

Strany 65

Section 19. CsiLogMonitor Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_BUSY Error: T

Strany 66

Section 19. CsiLogMonitor Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_BUSY Error: At

Strany 67

Section 19. CsiLogMonitor Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return LogMonitor.tranLog

Strany 68 - 14.1.2 Methods

Section 1. LoggerNet Server SDK Overview 5. A confirmation message similar to one below will appear. Click on Yes. 6. A new window titled Informa

Strany 69 - 14.1.3 Events

Section 19. CsiLogMonitor Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_FAIL Error: U

Strany 70

Section 19. CsiLogMonitor Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_FAIL Error: U

Strany 71

Section 19. CsiLogMonitor Control Reference LogMonitor.tranLogMonitorStop() Name LogMonitor.tranLogMonitorStop() Description This method will stop a

Strany 72

Section 19. CsiLogMonitor Control Reference Table of Possible failure codes. Enumeration Name Value Description lm_failure_unknown 0 Indicates t

Strany 73 - 15.1.2 Methods

Section 19. CsiLogMonitor Control Reference Description This event indicates there was an error with the connection to the LoggerNet server. This ev

Strany 74 - 15.1.3 Events

Section 19. CsiLogMonitor Control Reference Description This event indicates an error has occurred while trying to retrieve transaction log entries f

Strany 75

Section 19. CsiLogMonitor Control Reference 19-12

Strany 76

Appendix A. Server and Device Operational Statistics Tables The LoggerNet server and devices in the network map maintain statistics that help to desc

Strany 77

Appendix A. Server and Device Operational Statistics Tables Description: Records the total number of retires that the device experienced during the te

Strany 78

Appendix A. Server and Device Operational Statistics Tables Applies To: All Device Types Description: A running total of the number of communication

Strany 79

Section 2. CsiServer Control 2.1 Purpose of the CsiServer Control The CsiServer Control allows the user to start and stop the included, LoggerNet se

Strany 80 - 16.1.2 Methods

Appendix A. Server and Device Operational Statistics Tables A.2.10 Collection Enabled Column Name: “Collection Enabled” Column Definition Description

Strany 81 - 16.1.3 Events

Appendix A. Server and Device Operational Statistics Tables Applies To: 21X, CR7X, CR10, CR10X, CR500, CR510, CR23X, CR10T, CR10X-TD, CR510-TD, CR23X

Strany 82

Appendix A. Server and Device Operational Statistics Tables Applies To: 21X, CR7X, CR10, CR10X, CR500, CR510, CR23X, CR10T, CR10X-TD, CR510-TD, CR23X-

Strany 83 - 16.2.1 Properties

Appendix A. Server and Device Operational Statistics Tables A.2.20 Polling Active Column Name: “Polling Active” Column Definition Description: “Poll

Strany 84 - 16.2.2 Methods

Appendix A. Server and Device Operational Statistics Tables Type: uint4 Applies To: 21X, CR7, CR10, CR10X, CR500, CR510, CR23X Description: Relays the

Strany 85 - 16.3 Broker Interface

Appendix A. Server and Device Operational Statistics Tables shut itself down because its supply voltage has been to low. This information is read fr

Strany 86

Appendix A. Server and Device Operational Statistics Tables A-10 There is only one row defined for the table. The statistics available in this table

Strany 88 - 16.4.2 Methods

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Strany 89

Section 2. CsiServer Control 2-2 2.2.1 Properties • applicationWorkDir As String • buildDate As String (read-only) • logFileDir As String • serv

Strany 90 - 16.5 Table Interface

Section 3. Developing an Application Using the CsiServer Control 3.1 Purpose This section shows by example how to build an application using the SDK

Strany 92 - 16.6.2 Methods

Section 3. Developing an Application Using the CsiServer Control CsiLogMonitor 1.0 Type Library CsiServer 1.0 Type Library Check the box next to the

Strany 93

Section 3. Developing an Application Using the CsiServer Control In order to stop the LoggerNet server, use the method stopServer(). A basic example

Strany 94 - 16.7 Column Interface

Section 3. Developing an Application Using the CsiServer Control 3-4

Strany 95

Section 4. CsiCoraScript Control 4.1 Purpose of the CsiCoraScript Control The CsiCoraScript control provides the power to administer the LoggerNet s

Strany 96

Section 4. CsiCoraScript Control 4.3.1 Setting up a Network Some of the commands that can be used when initially setting up a datalogger network on

Strany 97

Section 4. CsiCoraScript Control 4.3.2.1 Table-Data Dataloggers The LoggerNet server, by default, creates a collect area for the Public or InLocs ta

Strany 98

Section 4. CsiCoraScript Control 4-4 Collect area names must always be unique. Therefore, if an attempt is made to create a collect area with exactl

Strany 99

Section 5. Developing an Application Using the CsiCoraScript Control 5.1 Purpose This section shows an example of how to build an application using

Strany 100

Section 5. Developing an Application Using the CsiCoraScript Control Check the box next to the CsiCoraScript 1.0 Type Library, click Apply, and then

Strany 101

Section 5. Developing an Application Using the CsiCoraScript Control Private Sub cmdConnect_Click() 'Connect using the default logon settings. C

Strany 102

Campbell Scientific, Inc. Software SDK End User License Agreement (EULA) NOTICE OF AGREEMENT: Please carefully read this EULA. By installing or using

Strany 103

Section 5. Developing an Application Using the CsiCoraScript Control 5-4

Strany 104 - 17.1.2 Methods

Section 6. CsiBrokerMap Control 6.1 Purpose of the CsiBrokerMap Control The CsiBrokerMap control gives developers access to the broker map, which is

Strany 105

Section 6. CsiBrokerMap Control 6.3 How Collections Work The CsiBrokerMap uses the concept of collections in its implementation. Collections provide

Strany 106

Section 6. CsiBrokerMap Control 6.4 CsiBrokerMap Interfaces The following interfaces are included in the CsiBrokerMap control: • Broker • Broker

Strany 107 - E_CSI_NOT_CONNECTED

Section 6. CsiBrokerMap Control 6.4.2.2 Methods • item(id) As Broker • _NewEnum() (GetEnumerator() in .NET) 6.4.3 Broker Interface See the Refer

Strany 108

Section 6. CsiBrokerMap Control 6.4.6 ColumnCollection Interface See the Reference Section for descriptions of these properties and methods. 6.4.6.

Strany 109

Section 6. CsiBrokerMap Control 6-6

Strany 110

Section 7. Developing an Application Using the CsiBrokerMap Control 7.1 Purpose This section shows by example how to build an application using the

Strany 111 - 17.1.3 Events

Section 7. Developing an Application Using the CsiBrokerMap Control 2. Start a new project (File | New Project | Standard EXE | OK). This will open

Strany 112

Section 7. Developing an Application Using the CsiBrokerMap Control Now that the interface has been designed, the code can be organized to accomplish

Strany 113

7) If the software program you develop requires you, your customer, or a third party to use additional licensable software from Campbell Scientific,

Strany 114

Section 7. Developing an Application Using the CsiBrokerMap Control 7-4 "." & t.Name & "." & c.Name, c.Name)

Strany 115

Section 8. CsiDatalogger 8.1 Purpose of the CsiDatalogger Control The CsiDatalogger control allows the developer to manage datalogger functions thro

Strany 116

Section 8. CsiDatalogger 8-2 8.3.2 Methods • clockCancel() • clockCheckStart() • clockSetStart() • loggerConnectCancel() • loggerConnectStart(l

Strany 117

Section 9. Developing an Application Using the Datalogger Control 9.1 Purpose This section illustrates the use of the CsiDatalogger control. This c

Strany 118

Section 9. Developing an Application Using the Datalogger Control 2. Start a new project (File | New Project | Standard EXE | OK). This will open a

Strany 119

Section 9. Developing an Application Using the Datalogger Control Now that the interface has been designed, the code can be organized to accomplish t

Strany 120

Section 9. Developing an Application Using the Datalogger Control Private Sub cmdDataloggerConnect_Click() 'Create an active connection to the

Strany 121

Section 9. Developing an Application Using the Datalogger Control Private Sub cmdCheck_Click() 'Check the clock on the datalogger. If DataLo

Strany 122

Section 9. Developing an Application Using the Datalogger Control Private Sub cmdDataStart_Click() 'Begin a manual poll to retrieve data If

Strany 123

Section 9. Developing an Application Using the Datalogger Control Private Sub cmdRetrieve_Click() 'Get the current program from the datalogger

Strany 124

application. This information should appear on the first window the user will see. WARRANTIES: The following warranties are in effect for ninety (90)

Strany 125 - Reference

Section 9. Developing an Application Using the Datalogger Control 9-8

Strany 126 - 207.201.118.35

Section 10. CsiDataSource Control 10.1 Purpose of the CsiDataSource Control The CsiDataSource control allows an application to monitor data collecte

Strany 127

Section 10. CsiDataSource Control 10.3 CsiDataSource Interfaces The following interfaces are used in the CsiDataSource control: • DSource – the con

Strany 128 - 18.1.2 Methods

Section 10. CsiDataSource Control 10.3.2.1 Properties • advisorName As String • orderOption As csidsOrderOptionType • startDate As Date • startF

Strany 129 - 18.1.3 Events

Section 10. CsiDataSource Control 10-4 10.3.5 Record See the Reference Section for descriptions of these properties, methods, and events. 10.3.5.1

Strany 130

Section 11. Developing an Application Using the CsiDataSource Control 11.1 Purpose The CsiDataSource control primarily monitors data residing in the

Strany 131

Section 11. Developing an Application Using the CsiDataSource Control 3. View the toolbox for this new project (VB 6 Main Menu | View | Toolbox). 4

Strany 132

Section 11. Developing an Application Using the CsiDataSource Control Now that the interface has been designed, the code can be organized to accompli

Strany 133

Section 11. Developing an Application Using the CsiDataSource Control 11-4 Private Sub DSource_onAdviseRecord(ByVal myAdvisor As Object, _ ByVal myRe

Strany 134

Section 12. CsiLogMonitor Control 12.1 Purpose of the CsiLogMonitor Control The CsiLogMonitor Control provides access to log message from the Logger

Strany 135 - 18.2 Advisor Interface

There is no written or implied warranty provided with the LoggerNet Server SDK software other than as stated herein. Developer agrees to bear all war

Strany 136

Section 12. CsiLogMonitor Control 12-2 12.2 CsiLogMonitor Interface See the Reference section in this manual for detailed descriptions of these prop

Strany 137

Section 13. Developing an Application Using the CsiLogMonitor Control 13.1 Purpose This section shows an example of how to build an application usin

Strany 138

Section 13. Developing an Application Using the CsiLogMonitor Control Check the box next to the CsiLogMonitor 1.0 Type Library, click Apply, and clos

Strany 139

Section 13. Developing an Application Using the CsiLogMonitor Control Private Sub cmdConnect_Click() 'Connect using the default logon settings.

Strany 140

Section 13. Developing an Application Using the CsiLogMonitor Control 13-4 Stop monitoring logs with the commLogMonitorStop() and tranLogMonitorStop(

Strany 141

Section 14. CsiServer Control Reference 14.1 Server Interface 14.1.1 Properties Server.applicationWorkDir Name Server.applicationWorkDir As String

Strany 142

Section 14. CsiServer Control Reference Server.logFileDir Name Server.logFileDir As String Description This property specifies the location where th

Strany 143 - 18.2.2 Methods

Section 14. CsiServer Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_FAIL Error: Unexp

Strany 144

Section 14. CsiServer Control Reference Server.tcpPortEx Name Server.tcpPortEx As Long Description This property sets the TCP port that the LoggerNet

Strany 145

Section 14. CsiServer Control Reference Server.stopServer() Name Server.stopServer() Description This method will stop the limited LoggerNet server

Strany 146 - 18.3.2 Methods

LoggerNet Server Software Development Kit Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use t

Strany 147

Section 14. CsiServer Control Reference 14-6

Strany 148

Section 15. CsiCoraScript Control Reference 15.1 CoraScript Interface 15.1.1 Properties CoraScript.serverConnected Name CoraScript.serverConnected

Strany 149 - 18.5 Record Interface

Section 15. CsiCoraScript Control Reference CoraScript.serverLogonPassword Name CoraScript.serverLogonPassword As String Valid Values If security is

Strany 150

Section 15. CsiCoraScript Control Reference CoraScript.serverPort Name CoraScript.serverPort As Long Description Specifies the TCP port number that

Strany 151 - 18.5.2 Methods

Section 15. CsiCoraScript Control Reference CoraScript.serverConnect() Name CoraScript.serverConnect() Description This method attempts to connect t

Strany 152

Section 15. CsiCoraScript Control Reference CoraScript_onServerConnectStarted() Name onServerConnectStarted() Description The control has connected t

Strany 153 - 18.6 RecordCollection

Section 15. CsiCoraScript Control Reference 15-6

Strany 154 - 18.7 Value Interface

Section 16. CsiBrokerMap Control Reference 16.1 BrokerMap Interface 16.1.1 Properties BrokerMap.serverName Name BrokerMap.serverName As String Desc

Strany 155

Section 16. CsiBrokerMap Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_BUSY Error: At

Strany 156

Section 16. CsiBrokerMap Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_BUSY Error: At

Strany 157 - 63.255.173.183

LoggerNet Software Development Kit Table of Contents 4.4 CsiCoraScript Interface...

Strany 158

Section 16. CsiBrokerMap Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal Return 16.1.2 Methods Broke

Strany 159 - 19.1.2 Methods

Section 16. CsiBrokerMap Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_ALREADY_CONNECT

Strany 160

Section 16. CsiBrokerMap Control Reference BrokerMap_onFailure() Name onFailure(BrokerMapFailureType failure_code) Description When the BrokerMap co

Strany 161

Section 16. CsiBrokerMap Control Reference BrokerMap_onTableDeleted() Name onTableDeleted(Object Broker, Object Table) Description This event gets c

Strany 162 - 19.1.3 Events

Section 16. CsiBrokerMap Control Reference 16.2.2 Methods BrokerCollection.Item() Name BrokerCollection.Item(id) As Broker Description A Broker can

Strany 163

Section 16. CsiBrokerMap Control Reference BrokerCollection._NewEnum() Name BrokerCollection._NewEnum() — Return the next broker in the broker map se

Strany 164

Section 16. CsiBrokerMap Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return. Broker.type Name B

Strany 165

Section 16. CsiBrokerMap Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return Broker.allStarted Nam

Strany 166

Section 16. CsiBrokerMap Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal Return 16.4 TableCollection

Strany 167 - A.1.3 Retries

Section 16. CsiBrokerMap Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_ARRAY_OUT_OF_BO

Strany 168 - A.2.5 Total Attempts

LoggerNet Software Development Kit Table of Contents 8. CsiDatalogger ...8-1 8.1 Purpose of

Strany 169 - A.2.9 Last Clock Difference

Section 16. CsiBrokerMap Control Reference 16.5 Table Interface 16.5.1 Properties Table.interval Name Table.interval As Long Description The time

Strany 170 - A.2.14 Collection State

Section 16. CsiBrokerMap Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return Table.size Name Tabl

Strany 171 - A.2.17 Values in Holes

Section 16. CsiBrokerMap Control Reference Table.start_expansion Name Table.start_expansion() Description If the BrokerMap autoExpand property has be

Strany 172 - A.2.19 Line State

Section 16. CsiBrokerMap Control Reference Prototypes ColumnCollection.Item(Number) - Array index. ColumnCollection.Item(String) - Table name. COM R

Strany 173

Section 16. CsiBrokerMap Control Reference 16.7 Column Interface 16.7.1 Properties Column.description Name Column.description As String Description

Strany 174 - A.2.29 Collect Retries

Section 16. CsiBrokerMap Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return Column.type Name Col

Strany 175 - A.3 Server Statistics

Section 16. CsiBrokerMap Control Reference Name Value Description dt_CsiAscii 11 fixed-length string dt_CsiAsciiZ 16 null-terminated variable-

Strany 176 - A.3.3 Used Virtual Memory

Section 16. CsiBrokerMap Control Reference Column.writable Name Column.writable As Long Description This property is read-only and describes whether

Strany 177

Section 16. CsiBrokerMap Control Reference 16-22

Strany 178

Section 17. CsiDatalogger Control Reference 17.1 Datalogger Interface 17.1.1 Properties Datalogger.clockBusy Name Datalogger.clockBusy As Boolean

Komentáře k této Příručce

Žádné komentáře