Campbell-scientific SR50A Distance Sensor Uživatelský manuál Strana 1

Procházejte online nebo si stáhněte Uživatelský manuál pro Senzory Campbell-scientific SR50A Distance Sensor. Campbell Scientific SR50A Distance Sensor User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - SR50A Sonic Ranging Sensor

SR50A Sonic Ranging SensorRevision: 1/11Copyright © 2007-2011Campbell Scientific, Inc.

Strany 2 - Warranty and Assistance

SR50A Sonic Ranging Sensor 3.3 SDI-12 Operation SDI-12 is a Serial Digital Interface standard that is used for communication between data recorders a

Strany 3 - SR50A Table of Contents

SR50A Sonic Ranging Sensor The different commands are entered as options in the SDI-12 recorder instruction. The major difference between the various

Strany 4

SR50A Sonic Ranging Sensor SDI-12 Command Command Function/Description Values Returned ?! Address Query a aAb! Change Address command b is the ne

Strany 5

SR50A Sonic Ranging Sensor 3.5 RS-485 Operation The SR50A sensor comes from the factory with the internal jumpers set to SDI-12 mode. To use the SR5

Strany 6

SR50A Sonic Ranging Sensor FIGURE 1. SR50A to MD485 Wiring 3.6 RS-232 and RS-485 Settings Once the jumpers are set for RS-232 operation a terminal

Strany 7

SR50A Sonic Ranging Sensor The Initial menu will look as follows: The following is a summary of settings that can be changed on the SR50A RS-232 or

Strany 8 - 3. Operation

SR50A Sonic Ranging Sensor Setting Description Options Default Value Quality Output On Off Off Temperature Output On Off Off Output valid only for

Strany 9 - 3.1 Quality Numbers

SR50A Sonic Ranging Sensor 3.6.3.2 Auto Measure Auto Output Mode In this mode the SR50A will automatically exit its low power mode, initiate a measur

Strany 10 - 3.3 SDI-12 Operation

SR50A Sonic Ranging Sensor 3.6.6 Measurement Interval Units This setting is only applicable if either the Auto Measure Polled Output or the Auto Meas

Strany 11

SR50A Sonic Ranging Sensor 3.7 Serial Commands 3.7.1 Setup Command The setup command places the SR50A in the serial setup mode. This command should

Strany 12 - 3.4 RS-232 Operation

Warranty and Assistance The SR50A SONIC RANGING SENSOR is warranted by Campbell Scientific, Inc. to be free from defects in materials and workmanship

Strany 13 - 3.5 RS-485 Operation

SR50A Sonic Ranging Sensor 3.8 RS-232/RS-485 Data Output Format 3.8.1 Measurement Output The measurement output string for the SR50A is as follows:

Strany 14

SR50A Sonic Ranging Sensor VXVVV If X is a 1, then no watchdog errors have occurred. VVXXX The 3 digits XXX are for factory use and should always read

Strany 15

SR50A Sonic Ranging Sensor BBBBB This is the checksum of the boot code. WWWWW This is the checksum of the firmware. CC This is a 2 character checksum

Strany 16 - 3.6.2 Address

SR50A Sonic Ranging Sensor FIGURE 2. Beam Angle Clearance 4.2 Mounting Height Any target to the SR50A should be at least 19.7 in (50 cm) or more f

Strany 17 - 3.6.5 Distance to Ground

SR50A Sonic Ranging Sensor 4.3 Mounting Options There are two standard mounting options available for the SR50A sensor. The first is the SR50A Mounti

Strany 18

SR50A Sonic Ranging Sensor FIGURE 6. SR50A - Mounted using a NU-RAIL Fitting and 19484 Mounting Stem SR50A with 6-plate gill radiation shield – the

Strany 19 - 3.7 Serial Commands

SR50A Sonic Ranging Sensor It is recommended that the transducer housing assembly (part number 19486 – Transducer Maintenance Kit) be replaced every 3

Strany 20 - 3.8.1 Measurement Output

SR50A Sonic Ranging Sensor FIGURE 8. Remove 6 Screws from the Transducer Housing FIGURE 9. Remove Transducer Housing and Disconnect Wires 21

Strany 21

SR50A Sonic Ranging Sensor FIGURE 10. Location of Desiccant in Transducer Housing Assembly FIGURE 11. Remove and Replace Desiccant 22

Strany 22 - 4.1 Beam Angle

SR50A Sonic Ranging Sensor FIGURE 12. Remove the 2 Flat Philips Screws to Expose the PCB Carefully reassemble in reverse order. 7. Jumper Settings

Strany 23 - 4.2 Mounting Height

SR50A Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab for

Strany 24 - 4.3 Mounting Options

SR50A Sonic Ranging Sensor The SR50A can be configured with either SDI-12, RS-232 or RS-485 communications. Shunt jumpers can be located on any of th

Strany 25 - 5. Maintenance

SR50A Sonic Ranging Sensor • Power can now be applied to the SR50A by connecting the connector and applying power to the sensor. The Green LED shoul

Strany 26

SR50A Sonic Ranging Sensor 10. Datalogger Program Examples In the following datalogger program examples only the CR1000 and the CR10X dataloggers are

Strany 27

SR50A Sonic Ranging Sensor 10.1.2 CR1000 Example (RS-232 Mode) 'CR1000 Series Datalogger 'In this example, the SR50A is mounted 2.5 meters

Strany 28

SR50A Sonic Ranging Sensor 'Measure the 107 temperature sensor: Therm107 (Air_Temp,1,1,Vx1,0,250,1.0,0) 'Use Air_Temp to calcula

Strany 29 - 7. Jumper Settings

SR50A Sonic Ranging Sensor 5: Z=SQRT(X) (P39) 1: 6 X Loc [ Mult1 ] 2: 6 Z Loc [ Mult1 ] ;Distance to the Snow Surface is obtain

Strany 30 - 8. SR50A Firmware Updates

SR50A Sonic Ranging Sensor 10.2 SR50AT Examples 10.2.1 CR1000 Example (SDI-12 “M4!”) 'CR1000 Series Datalogger 'The following sample progr

Strany 31 - 9. Data Interpretation

SR50A Sonic Ranging Sensor 'Main Program BeginProg Scan (60,Sec,0,0) PanelTemp (PTemp,250) Battery (Batt_volt) 'Once installed

Strany 32 - 10.1 SR50A Examples

SR50A Sonic Ranging Sensor 10.2.2 CR1000 Example (RS-232 Mode) 'CR1000 Series Datalogger 'In this example, the SR50AT is mounted 2.5 meter

Strany 33

SR50A Sonic Ranging Sensor 'Subtract the corrected distance from the initial distance of the SR50A to the ground: Snow_Depth=Initial_Distan

Strany 34

SR50A Table of Contents ii 4. Sensor Mounting and Installation ...16 4.1 Beam Angle ...

Strany 35

SR50A Sonic Ranging Sensor 34 6: Real Time (P77)^30811 1: 1220 Year,Day,Hour/Minute (midnight = 2400) 7: Sample (P70)^20443 1: 1 Reps 2:

Strany 37

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Strany 38

Warning! Always disconnect the sensor before opening. This Device complies with Part 15 of the FCC Rules. Operation is subject to the following two c

Strany 40 - 11. Warnings/Cautions

SR50A Sonic Ranging Sensor 1. Specifications Power Requirements: 9 to 18 Vdc Power Consumption: Quiescent SDI-12 Mode < 1.0 mA RS-232/RS485

Strany 41

SR50A Sonic Ranging Sensor 2. Introduction The SR50A Sonic Ranging Sensor measures the distance from the sensor to a target. The most common applica

Strany 42

SR50A Sonic Ranging Sensor 3.1 Quality Numbers Measurement quality numbers are also available with output data; these give an indication of the measu