LI200X-LC PYRANOMETER FOR METDATA1
5
EXAMPLE 2. Sample Instructions used to Measure a Daily Total Flux Density with a CR10(X)/21X
;{CR10X}
;
*Table 1 Program
01: 10 Execution Interval (seconds)
01: Volt (Diff) (P2)
1: 1 Reps
2: 22 ± 7.5 mV 60 Hz Rejection Range
3: 3 DIFF Channel
4: 1* Loc [ MJ_m2 ]
5: .002** Mult
6: 0 Offset
;Set negative values to zero.
;
02: If (X<=>F) (P89)
1: 1* X Loc [ MJ_m2 ]
2: 4 <
3: 0 F
4: 30 Then Do
03: Z=F (P30)
1: 0 F
2: 0 Exponent of 10
3: 1* Z Loc [ MJ_m2 ]
04: End (P95)
05: If time is (P92)
1: 0 Minutes (Seconds --) into a
2: 1440 Interval (same units as above)
3: 10 Set Output Flag High (Flag 0)
06: Real Time (P77)
1: 0110 Day,Hour/Minute
07: Totalize (P72)
1: 1 Reps
2: 1* Loc [ MJ_m2 ]
-Input Locations-
1 MJ_m2
*
Proper entries will vary with program.
**
See Table 4-1 for alternative multipliers.