CS420-L and CS425-L Pressure Transducers
7.2.2 Instruction 9 (6-Wire Full Bridge w/Excitation)
7.2.2.1 Wiring
Datalogger CS420-L/CS425-L
Excitation E1 Red (Supply +)
Input H1 Orange (Monitor +)
Input L1 Black (Monitor -)
Input H2 Yellow (Output +)
Input L2 Blue (Output -)
G White (Supply -)
G Clear (Shield)
7.2.2.2 Edlog Program
; Measure one 6-wire DRUCK Sensor.
* Table 1 Program
01: 5 Execution Interval (seconds)
1: Full Bridge w/mV Excit (P9)
1: 1 Reps
2 25* 5000 mV, 60Hz Rejection, slow Ex Range
3: 22** 50 mV, 60 Hz Rejection, Slow Br Range
4: 1 DIFF Channel
5: 1 Excite all reps w/Exchan 1
6: 5000 mV Excitation
7: 1 Loc [DEPTH_FT]
8: 2.3529 Mult
9: -0.49 Offset
*For 21X use Range Code 5
**For 21X use Range Code 3
; Every 60 minutes output the array ID, time,
; and average water depth in feet
2: If time is (P92)
1: 0000 Minutes into a
2: 60 Minute Interval
3: 10 Set output flag high
3: Real Time (P77)
1: 110 Day, Hour/Minute (midnight = 0000)
4: Average (P71)
1: 1 Reps
2 1 Loc [DEPTH_FT]
14