INSTRUCTION MANUAL
NL120 Ethernet Module
Revision: 3/14
Copyright © 2006- 2014
Campbell Scientific, Inc.
Zobrazit stránku 0
1 2 3 4 5 6 ... 19 20

Shrnutí obsahu

Strany 1 - INSTRUCTION MANUAL

INSTRUCTION MANUAL NL120 Ethernet Module Revision: 3/14 Copyright © 2006- 2014 Campbell Scientific, Inc.

Strany 2

NL120 Ethernet Module FIGURE 4-2. LoggerNet setup 4.2.3 Step 3 – Connect You are now ready to connect to your datalogger using the LoggerNet Connec

Strany 3 - Warranty

NL120 Ethernet Module Cable Requirements: Use a straight-through Ethernet cable when the cable is run from the hub to the NL120. Use a crossover Eth

Strany 4 - Assistance

NL120 Ethernet Module 6.1 Communicating over TCP/IP Once the datalogger, the NL120, and LoggerNet have been set up as described in Sections 4.1, Phys

Strany 5 - Table of Contents

NL120 Ethernet Module 6.1.2 Datalogger-to-Datalogger Communication Communication between dataloggers is possible over TCP/IP. In order to do this, a

Strany 6

NL120 Ethernet Module Records Display must be manually refreshed. In addition, links are provided to all HTML files, all XML files, and all JPEG file

Strany 7 - NL120 Ethernet Module

NL120 Ethernet Module FIGURE 6-2. FTP root directory FIGURE 6-3. FTP USR directory 9

Strany 8 - 4. Quickstart

NL120 Ethernet Module In order to use FTP, the datalogger’s FTP User Name and FTP Password must be set. This is done using Device Configuration Utili

Strany 9

NL120 Ethernet Module PROGRAM 'CR1000 'FTPClient.cr1 Public Result1, Result2 BeginProg Scan (20,Sec,1,1) Result1 = FTPClient("

Strany 10 - 5. Specifications

NL120 Ethernet Module 6.6.2 Serial Output The TCPOpen() instruction must be used first to open up a TCP socket. An example of this instruction is sh

Strany 13 - 6.2 HTTP Web Server

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Strany 14 - 6.3 FTP

Warranty “PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in materi

Strany 15

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Strany 16 - 6.3.2 FTP Client

Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to spec

Strany 17 - 6.5 Ping

Table of Contents ii

Strany 18 - 6.9 DNS

NL120 Ethernet Module 1. Introduction Campbell Scientific’s NL120 Ethernet Module enables 10Base-T Ethernet communications. It allows the datalogge

Strany 19

NL120 Ethernet Module 4. Quickstart This section describes the basics of communicating via Ethernet with the NL120. 4.1 Physical Setup Always powe

Strany 20

NL120 Ethernet Module d. Press the Apply button to save the changes and then close the Device Configuration Utility. A temporary IP address may be o